Crimp height: what it tells you and how tightly to control it

Crimp height shows the tool closed where it should, not that the crimp is good. Tolerances, micrometer error, Cpk at small samples and a response table.

By Wataru Sasaki, Editor. Written with AI assistance under human editorial supervision.

Published 5 November 2026. Updated 5 November 2026. 13 min read.

Desk research. The figures here are calculated from published formulas or taken from public records, with sources in the notes. None of it was measured on a production line.

Safety: not yet checked by a qualified engineer. This work can injure or kill. Use it to prepare questions, and follow the equipment maker's instructions, your risk assessment and the licensed standard.

Crimp height tells you whether the tool closed the terminal to its set-up position on this wire. It is a quick, non-destructive signal of compression that you can chart all shift. Hold it to the terminal maker's tolerance, which on TE's general table is ±0.05 mm for wire over 0.5 mm² and up to 6 mm², and ±0.02 mm on the finest wire,1 and react to shifts inside the tolerance as well as to readings outside it. A height inside tolerance does not prove a good crimp, because it cannot see cut strands, insulation in the barrel or the wrong crimper.

What the number stands for

Height stands in for compression. TE's tooling paper defines an area index: total area after crimping divided by the area of wire plus barrel before crimping, with 80% as a typical design point. It shows the minimum and maximum cross-sections that one terminal specification allows, a variation of ±3.5%.2 At a fixed crimp width the index moves in proportion to height. On TE's example crimp, 0.068 in (1.727 mm) high with a tolerance of ±0.002 in (±0.051 mm), the height tolerance alone is ±2.94%. That is the same order as the ±3.5% TE shows for one terminal, though the two are separate examples, so take it only as a sense of scale.

The same paper works out that a 2% change in crimp width costs 35% of that height tolerance,2 so changing the crimper can move compression with nobody touching the height adjustment.

Resistance can rise on either side of the window, as the harness manufacturing guide explains, and Molex sets its specification as a balance between electrical and mechanical performance across stranding, coatings and platings.3

How tight is tight enough?

Use the maker's figure for your terminal and wire. TE's general guideline steps the tolerance by wire size.1 The other columns are calculated.

Wire sizeTolerance (mm)±0.002 mm instrument uses±0.003 mm instrument usesLargest process sigma, Cp 1.33 (mm)Largest process sigma, Cp 1.67 (mm)
0.03 to 0.20 mm²±0.0210%15%0.00500.0040
Over 0.20 to 0.50 mm²±0.037%10%0.00750.0060
Over 0.50 to 6 mm²±0.054%6%0.01250.0100
Over 6 to 25 mm²±0.102%3%0.02510.0200
Over 25 to 50 mm²±0.151%2%0.03760.0299

"Uses" is the instrument's error as a share of half the tolerance. Molex's crimp micrometer quotes 0.001 mm resolution and ±0.002 mm accuracy,4 and Mitutoyo's 342 series 0.001 mm and a maximum permissible error of ±0.003 mm.5 Cp 1.33 is the level Molex calls acceptable for most applications,3 and your customer may ask for more. Sigma is width ÷ (6 × Cp).

These are TE's general values for its open barrel terminals, and a product specification overrides them.1 One TE 3.3 mm pitch receptacle specifies ±0.03 mm on an applicator even at 0.51 to 0.53 mm², where the general table would allow ±0.05 mm. Its hand tool table for the same wire gives 0.90 mm ±0.05 mm against 0.93 mm ±0.03 mm, so read the row for your tooling.6

Against the tolerance, the instrument's error is the small part. The larger unknown is what happens when a person places a point on a formed crimp, and neither maker publishes a repeatability figure for that. Molex recommends a gauge capability study.3 The table sizes the possible results, taking a range of gauge standard deviations as an illustration.

ToleranceGauge sd 0.001 mmGauge sd 0.002 mmGauge sd 0.003 mmGauge sd 0.005 mm
±0.02 mm15%30%45%75%
±0.03 mm10%20%30%50%
±0.05 mm6%12%18%30%
±0.10 mm3%6%9%15%

Each cell is 6 × gauge sd ÷ tolerance width. As Minitab reports the AIAG bands, under 10% is acceptable, 10 to 30% depends on the application and the costs, and over 30% is unacceptable.7 At ±0.02 mm a gauge sd of 0.002 mm already sits on the 30% line.

Measurement noise also lowers the capability you report, which Molex warns about for micro-terminals.3 A process truly at Cp 1.33 reads 1.14 through a gauge sd of 0.003 mm at ±0.02 mm, and 1.29 at ±0.05 mm. Target accuracy gets squeezed too. A process sigma of 0.004 mm at ±0.02 mm leaves only 0.004 mm off target before Cpk falls below 1.33, about the size of the micrometer's own error. At ±0.05 mm the same process has 0.034 mm of room.

Five pieces cannot give you a Cpk

Molex asks for at least five readings to confirm a set-up and at least 25 for capability, and says itself that set-up samples have limited statistical value.3 NIST says the usual interval needs at least 25 pieces and that capability studies generally need 100.8 A reading of 1.33 is worth this much at each size.

A sample reads Cpk 1.33. Where is the process? 95% interval by number of pieces 1.00 reads 1.33 n = 5 n = 10 n = 25 n = 50 n = 100 0 0.5 1.0 1.5 2.0 2.5
A sample that reads Cpk 1.33 has a 95% interval of 0.36 to 2.30 at 5 pieces, 0.93 to 1.73 at 25 and 1.13 to 1.53 at 100. Rows below 25 pieces are rough.
Pieces95% range on a reading of 1.3395% lower boundProcess truly at 1.00 reads 1.33 or moreProcess truly at 1.67 reads below 1.33Reading needed to claim 1.33 at 95%
50.36 to 2.300.5222.4%24.9%3.22
100.68 to 1.980.7911.2%17.7%2.20
250.93 to 1.731.002.5%6.6%1.76
300.97 to 1.691.031.6%4.7%1.71
501.05 to 1.611.100.3%1.4%1.61
1001.13 to 1.531.17under 0.1%0.1%1.52

The intervals use NIST's approximation, Cpk ± z × √(1/(9n) + Cpk²/(2(n - 1))), with z of 1.96 for the range and 1.645 for the lower bound.8 Below 25 pieces that is outside what NIST calls valid, so treat those rows as rough. As a cross-check, the exact chi-square interval on Cp gives 0.46 to 2.22 at 5 pieces and 0.96 to 1.70 at 25. The two probability columns are simulated: 400,000 runs per cell, centred normal process, independent pieces. In the same simulation the lower bound held about 97% of the time even at 5 pieces, so here it errs on the cautious side.

So 25 pieces reading 1.33 tells you, with 95% confidence, only that the process is above 1.00. A five-piece reading tells you the average is about where you put it, which is what a set-up check needs. Do not write a Cpk on it.

Short-run shops cannot run a 25-piece study on every set-up, and Molex says so. Its answer is to establish capability before the tool goes into production, then keep one control chart per tool and wire size across colour, length and set-up changes.3 Twenty set-ups at five readings each give you 100 readings and show how far set-ups differ from one another. Treat the result as a long-run figure. If set-ups vary as much as pieces do, the 95% range on a reading of 1.33 is about 1.07 to 1.61 in simulation, wider than the 100-piece row.

The chart also gives you a working answer to "how tightly?". Molex's limit for samples of five is the average of the means ± 0.577 × the average range.3 With an invented average range of 0.010 mm, that is ±0.006 mm around the average, well inside a ±0.05 mm tolerance. At that range the total sd is about 0.004 mm, so a gauge sd of 0.003 mm would be about half the variance on the chart. Run the gauge study before you chase the chart. The tolerance tells you what to reject, and the chart limits tell you when to go and look.

A reading outside tolerance is different from a shift inside it. Stop the tool and hold everything back to the last good reading, as in the pull test containment steps. Then look for the cause.

If your terminal and wire have no published height, ask the terminal maker. Do not interpolate: one TE sheet's rows for 0.31 to 0.38 mm² and 0.51 to 0.53 mm² differ by 0.13 mm, and a 0.5 mm² wire is in neither.6

A set-up routine

This is condensed from Molex's 21-step procedure for its own tooling,3 which has the detail. Where your press or applicator maker says otherwise, follow them. Disconnect power and refit guards around every adjustment.

  1. Check that the crimper and anvil are clean, unworn and right for this terminal and wire. Your target comes from the product specification or applicator log sheet.1
  2. Install the tooling, cycle it by hand, and check alignment and feed.
  3. Crimp samples under power and set, in this order, the cut-off tab and bell mouth, the conductor brush and the insulation position.
  4. Loosen the insulation crimp, because adjusting it can change the conductor crimp height slightly.
  5. Crimp at least five and measure each. Put the blade across the top of the crimp, mid-barrel and away from the bell mouth, and bring the point onto the bottom radius, not onto the extrusions. Use the ratchet where there is one and do not overtighten the point.45 Adjust until five are on target.
  6. Pull test the conductor crimp, then set the insulation crimp, crimp again and measure the conductor height again.
  7. Record the target, the readings, the tool, the terminal reel lot and the wire lot.

During the run, Molex says to check height every 250 to 500 parts, and to record the point on the chart before you adjust, so the chart shows the process and not your corrections.3 That interval is 50 to 100 minutes at 300 parts an hour, 12 to 25 minutes at 1,200 an hour and 5 to 10 minutes at 3,000 an hour. TE adds a check for each batch and after each change of terminal reel, wire, crimp tool or setting, and asks for regular microsections from the first crimp on.1

When the reading moves, what to look at first

The causes are from Molex's troubleshooting tables and control chart notes.3 The order of checks is an editorial suggestion, quickest first.

What you seeWhat it may meanLook firstAvoid
Every piece high, step changeLess compression. Molex links high height to wire pulling out at low forceWhat changed: wire vendor or stranding, insulation colour or hardness, terminal reel lot, tooling, press or its shut heightTurning it back before you know what changed
Every piece low, step changeMore compression. Molex links low height to wire breaking before the crimp at low force. TE warns over-compression favours flashThe same list, then flash and extrusions, and tool wearReading low as safe because the crimp feels tight
Shift inside tolerance after a jamDamaged toolingInspect the crimper and anvilAdjusting height
Shift when the operator changesMeasurementHave both measure the same parts with the same gaugeAdjusting height
Shift at a new reel or wire lotMaterial. This one may justify an adjustmentConfirm part numbers, then adjust and note it on the chartAdjusting without a note
Shift after the insulation crimp was changedThe two crimps interactRe-measure and re-set the conductor crimpTreating it as a new fault
Same average, wider scatterDamaged, loose or worn tooling; wire or terminal variability; measurement error; too much spring-back from over-crimping; cut or missing strandsTool tightness, then strip quality, then a gauge checkChasing single readings
Height on target, pull force lowCut or nicked strands, no bell mouth or brush, a thin terminal or light serrationsHow the pull test failed, then strip qualityAdjusting height to chase pull force before you have the failure mode

Why a height inside tolerance does not prove a good crimp

TE calls crimp height "the overriding quality characteristic", and in the same document asks for microsections, pull force checks and, on semi-automatic and automatic machines, preferably crimp force monitoring.1 Height is the check you can afford to run often, and the others cover what it cannot see.

On a press, the closing point is set mechanically. Molex defines shut height as a distance at bottom dead centre, lists a changed shut height among the causes of off-target height, and lists cut or missing strands as a source of scatter.3 The inference is that a press closes to about the same place whether or not every strand is there, and the reading moves only a little. Presses do flex under load,9 so a crimp with fewer strands may read slightly low, but we found no published figure.

TE's area index can size what that gap hides. Hold the crimped area fixed, assume the barrel has half the area of the wire (an invented ratio), and take out 2 of 19 strands. The index goes from 80 to 86.0, or 85.3 to 87.0 for barrel ratios of 0.7 and 0.3, well beyond the ±3.5% TE shows for one terminal. To get back to 80 the height would have to fall by 7.0%, which is 0.121 mm on a 1.727 mm crimp, more than twice the ±0.051 mm tolerance. In this illustration, the micrometer can read on target while the copper sees a crimp 0.12 mm too high.

You can test this on your own wire. Crimp sets with one, two and three strands removed and measure them. Schleuniger suggests the same exercise for setting up a crimp force monitor.9 It shows how much your chart would notice on that terminal.

FaultWhy height can miss itWhat can catch it
Cut or missing strandsThe tool closes to about the same placeVisual check when fanning the bundle, microsection, crimp force monitor
Insulation under the conductor crimpHeight measures the outside of the crimpThe window between the crimps, which TE says must show the insulation end
Wrong crimper widthHeight can be right with the wrong widthMeasuring crimp width at the bottom of the crimp at set-up. TE says it does not work as a running production control
Nicked strands, no bell mouth, no brushA height reading does not measure strand conditionVisual check, pull test
Thin terminal stock, light serrationsSame height, less gripPull test, then the terminal maker
Open seam, uneven roll-in, flash, cracksInside or beside the formMicrosection against TE's criteria

A monitor has limits as well. TE asks for it to flag a loss of more than 9% of the conductor section through cut strands, and insulation over more than half the crimp length.1 Worked through, a monitor set to that rule should flag 1 of 7 strands or 2 of 19, and need not flag 1 of 19 or 5 of 65. Whether it can depends on the application. Schleuniger, a monitor supplier, says companies usually find the best headroom, the gap in peak force between a crimp with wire and one without, is 30 to 40%, and that harder terminals shrink it. Ask for that figure before you rely on the monitor. The same article says it often finds monitors switched off on shop visits.9 Molex wants the operator to fan each bundle and check it by eye as standard practice,3 and a look at the brush is the quick way to notice strands that did not make it into the barrel.

Notes

  1. TE Connectivity, Application Specification 114-18022, Rev K, 2011, general guidelines for contacts with open crimp barrels, copy hosted by Farnell. This is Rev K, the copy we could open. Check TE for a later revision. Written first for the automotive industry; it says it can be used for other industries. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7

  2. TE Connectivity, Crimp Tooling: Where Form Meets Function, 2011, white paper, copy hosted by ChipDip. A tool maker's paper, used here for its definitions and worked examples and not for its product claims. ↩ ↩2

  3. Molex, Quality Crimping Handbook, order no. 63800-0029, revision C, 2009, copy hosted by DigiKey. Written for Molex open barrel terminals and tooling. ↩ ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12

  4. Molex, Crimp Height Micrometer 63800-2850, application tooling specification, copy hosted by ChipDip. ↩ ↩2

  5. Mitutoyo, Crimp Height Micrometers, Series 342, catalogue page, copy hosted by a distributor. ↩ ↩2

  6. TE Connectivity, Application Specification 114-106094, Rev D, copy hosted by Farnell. ↩ ↩2

  7. Minitab, More on how to interpret gage output. Software vendor's blog, reporting the AIAG guidelines. The AIAG manual itself was not read. ↩

  8. NIST/SEMATECH, e-Handbook of Statistical Methods, section 6.1.6, What is process capability?. US government publication. It assumes normally distributed data. ↩ ↩2

  9. G. Garcia-Cota, Schleuniger, Crimp Force Monitoring: The Recipe for Success, supplier article. ↩ ↩2 ↩3